![Multiva Cerex 300 Comfort Operation And Maintenance Manual Download Page 162](http://html1.mh-extra.com/html/multiva/cerex-300-comfort/cerex-300-comfort_operation-and-maintenance-manual_1856359162.webp)
Figure. 7.9.1.2. - 222. Fastening the coulter
2. Set the lowest rubber damper (3) in its place and lift the coulter (1) against the mounting
beam.
3. Install the remaining 3 rubber dampers (5).
4. Replace the washer (2).
5. Install the 4 fastening bolts and nuts (4) and tighten the bolts evenly to eliminate any gap
between the mounting plates.
Use new locknuts with a strength rating of 10 to fasten.
Figure. 7.9.1.2. - 223. Connecting coulter hoses
6. Connect the hoses (2, 3) in the appropriate locations in the coulter.
The front hose (2) comes from the fertiliser hopper and the rear hose (3) comes
from the seed hopper.
7. Tighten the hose clamps (1,4).