PAGE 30 — DA7000SSA2/SSA2GH GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 (03/26/15)
OPERATION
4. If the engine does not start within 10 seconds after the
key is turned to the
START
position, wait for about 30
seconds and repeat the procedure as described in
steps 1-3.
5. When the engine starts, the oil pressure light and
charge light should go out. If these lights stay on,
immediately stop the engine and check the system and
wiring (refer to the Engine Operation Manual).
6. Let the engine idle for five minutes with the
Idle Control
Switch
(Figure 23) placed in the
ON
position.
Figure 23. Idle Control Switch (ON)
Output Voltage Verification
1. Place
main
circuit breaker (Figure 24) in the
ON
position.
Figure 24. Main Circuit Breaker (ON)
NOTICE
Placing the idle control switch (Figure 23) in the
OFF
position allows the engine to operate at a maximum
speed of about 3600 RPM's.
When the idle control switch is placed in the up position
(
ON
), the generator will run at idle speed (2200 RPM's)
until a load is applied, at that time the engine speed
will increase to 3600 RPM's as long as a load is being
applied.
When the load is not in use, the engine speed will drop
back to the idle mode after about 3 seconds.
ON
I
O
OFF
2. Place auxiliary
circuit breakers (Figure 25) in the
ON
position.
Figure 25. Auxiliary Circuit Breakers (ON)
3. Read the voltmeter on front panel of generator (Figure
26) and verify that 120 VAC is displayed. Using an
external voltmeter as shown in Figure 26, verify that
120 VAC is present at the 120V twist-lock and duplex
receptacles.
Figure 26. 120V GFCI/L5-30R Receptacles
V
240
120
NEMA 5-20R
120VAC
X
L5-30R
W
OF F
V~
V
300 mV
A
A~
V
COM
120 VAC
NOTICE
When using a combination of dual receptacles, total
load should not exceed the rated capacity of the
generator.
Summary of Contents for DA7000SSA2
Page 64: ...PAGE 64 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 GENERATOR ASSY...
Page 74: ...PAGE 74 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 BATTERY ASSY...
Page 76: ...PAGE 76 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 MUFFLER ASSY...
Page 78: ...PAGE 78 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 FUEL TANK ASSY...
Page 80: ...PAGE 80 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ENCLOSURE ASSY...
Page 82: ...PAGE 82 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ENCLOSURE ASSY...
Page 159: ...DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 PAGE 159 NOTES...