34
35
Programming Options
Programming Options
Contact ID Base Message
/ Default: 18095099900
DTMF
* 2 0
X X X X X X X X X X
#
This is the default base Contact ID message, refer
to the format template table for individual alarms.
Line Fault Switch Delay
/ Default: 300
DTMF
* 2 5
3 0 0
#
Switching delay for the Mode3 Relays on failure
restore (in milliseconds), Default 300mS. This must
be very quick, as the MC4P will connect directly
to the attached panel to take control of the
communications.
Poll Fail Detection Delay
/ Default: 150
DTMF
* 2 6
1 5 0
#
This monitors all paths for polling within the
programmed time; this is mapped to the relays.
Default 150 seconds. See option 38 for relay map.
6HHRSWLRQIRUHQDEOLQJ&,'QRWLÀFDWLRQ
Multicom/PSTN Priority
/ Default: 1
DTMF
* 1 1
1
#
0 =
Multicom is the priority line for the attached
panel,
1 =
PSTN is the primary line for the attached
alarm panel
External Panel Programming Timer
/ Default: Blank
DTMF
* 1 3
X X
#
Program this in minutes. This feature allows
bypassing of the Multicom for a programmed
period, so that you can program an attached
panel. Connects PSTN to PANEL.
PSTN Fault Threshold (Volts)
/ Default: 3
DTMF
* 1 7
0 3
#
Voltage to detect line failure at (3V default)
Contact ID Retry Delay
/ Default: 15
DTMF
* 1 8
1 5
#
Time delay between Contact ID retries (in
seconds), time is based on the start of dialling,
default 15 seconds.