Mod. 6609d-6612d:
Automatic Forms Cutter
13.12.2006
-21-
3.2.1.5 Parameter e)
Counter Function
The machine can carry out a
counter function
after reaching the number of forms preset in param eter d)
Counter
. Available functions are "NONE" - "STOP" - "CUT" - "ONLINE #00/#01" und "PAUSE".
F4
- Press Input
F1
- Select a function (R)
F4
- Exit
NONE:
None of the functions listed below (the preset counter is not in use)
STOP:
The machine stops on reaching the preset number (SUB-counter returns to 00000).
CUT:
Edge cut only - a cross cut is carried out on reaching the preset number (SUB-counter
returns to 00000).
ONLINE #00/#01:
The preset counter can be programmed to output any online functions.
No
OMR system
is required (i.e. no reading head). If this function is selected the reading head will be
automatically dead. A maximum of 2 functions (3 wit h new software) can be performed,
one function several times, the other once only (e.g. collecting and enveloping or
selecting and enveloping). See Section 3.3.4.
PAUSE:
Pause (~3 sec) after reaching the preset number (the SUB-counter returns to 00000).
For manual removal or group separation with conveying belts.