Configuring the job computer for work
Calibrating the flow meter
7
30322453-02-EN
V4.20191001
47
CAUTION
Injury caused by working machine
If the function is activated when the implement is at a standstill, the driver can activate functions that
can otherwise only be activated during travel. This can cause injury to persons standing close to the
implement.
◦
Make sure that no one is close to the implement.
1.
On the work screen, press:
> (
) >
>
>
2.
In the “
Simulated speed
” parameter,
enter the speed to be simulated.
⇨
The desired speed will be simulated.
Calibrating the flow meter
You must calibrate the flow meter in the following cases:
▪
Prior to initial start-up.
▪
At the start of each season.
▪
If you notice that there are deviations between the applied quantity and the displayed quantity.
▪
After repairs performed on the flow meter.
NOTICE
Imprecise calibration
If the calibration is imprecise, the calculations will be very inaccurate and the application imprecise.
◦
Calibrate the flow meter very precisely.
CAUTION
Slurry or slurry residues
Risk of poisoning or corrosion
◦
Clean the tank before calibration.
◦
Only use clear water for the calibration.
◦
Wear required protective equipment.
The tank is filled with water. You need several hundred litres of water.
You have a method for measuring the quantity of applied water.
The pump is switched on.
1.
Drive the slurry tanker to a position where you can apply the water without any problems.
2.
On the work screen, press:
> (
) >
⇨
The “
FLOW METER
” screen appears.
Procedure
7.3
Procedure