1.4520.638 – MIC5 ISE Secon Short Circuit Cyl 9
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 9 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.639 – MIC5 ISE Secon Short Circuit Cyl 10
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 10 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.640 – MIC5 ISE Secon Short Circuit Cyl 11
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 11 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.641 – MIC5 ISE Secon Short Circuit Cyl 12
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 12 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.642 – MIC5 ISE Secon Short Circuit Cyl 13
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 13 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.643 – MIC5 ISE Secon Short Circuit Cyl 14
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 14 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.644 – MIC5 ISE Secon Short Circuit Cyl 15
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Short circuit in secondary circuit
of cylinder 15 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.