092 – SS Starter Speed Not Reached
Red alarm. Start terminated.
Associated parameter 2.1090.923
Cause
Corrective action
Minimum speed for flushing
process and ignition release was
not attained.
u
Check starter system.
093 – SS T-Preheat
Red alarm. Engine stop.
Associated parameter 2.1090.922
Cause
Corrective action
Preheating temperature too low
(limit value 2). coolant
temperature too low for engine
start.
1. Check preheating.
2. Check differential coolant pressure.
3. Check heating elements.
4. Check cabling.
094 – LO T-Preheat
Yellow alarm.
Associated parameter 2.1090.921
Cause
Corrective action
Preheating temperature too low
(limit value 1). coolant
temperature too low for engine
start.
1. Check preheating.
2. Check differential coolant pressure.
3. Check heating elements.
4. Check cabling.
095 – AL Prelubrication Fault
Red alarm. Start terminated.
Associated parameter 2.1090.920
Cause
Corrective action
Oil priming fault.
1. Check oil pressure, oil temperature, oil level.
2. Check oil priming pump.
104 – AL Eng Hours Counter Defect
Yellow alarm.
Associated parameter 1.8004.623
Cause
Corrective action
Engine hours counter defective.
Internal Engine Control Unit
fault.
u
Replace Engine Control Unit.
118 | Troubleshooting | MS15026/00E 2015-05