3.5 Engine – Start
Preconditions
☑
Generator not connected to network.
☑
Start interlock not active.
DANGER
Rotating and moving engine parts.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Before cranking the engine with starter system, make sure that there are no persons in the en-
gine's danger zone.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Starting engine
u
Start engine in accordance with starting sequence specifications (→ Page 40).
42 | Operation | MS15026/00E 2015-05
TIM-ID: 0000042719 - 001