1.4540.048 – SPI ADC Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.049 – Sense 5V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.050 – Sense -9V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.051 – Sense 12V Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.052 – ADC Test Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.053 – CAN Timing Changed
Yellow alarm. Initiated by TecJet.
Cause
Corrective action
CAN baud rate change detected.
1. Check settings.
2. Check cabling.
1.4540.054 – Exception Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
106 | Troubleshooting | MS15026/00E 2015-05
TIM-ID: 0000044566 - 002