
1.4540.041 – TecJet Internal Fault
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.042 – Keyswitch State
Red alarm. Initiated by TecJet.
Cause
Corrective action
Keyswitch cabling missing.
u
Check cabling.
1.4540.043 – Parameter Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.044 – Parameter Version Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.045 – Main EEP Read Fail
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.046 – Main EEP Write Fail
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.047 – Reading Parameters
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
MS15026/00E 2015-05
| Troubleshooting | 105
TIM-ID: 0000044566 - 002