4.2 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 95);
Coolant circuit
Check engine coolant level (→ Page 102).
Monitoring system
Carry out lamp test (see manufacturer's documentation).
Belt drive
Check condition of drive belt (→ Page 109).
Engine/generator control
system
Switch ON;
Select operating mode, e.g. MANUAL OPERATION, AUTOMATIC OPERATION.
MS15029/01E 2015-06
| Operation | 45
TIM-ID: 0000045439 - 002