1.4540.055 – Factory CAL Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart TecJet.
1.4540.056 – PWM Duty Cycle High Error
Red alarm. Initiated by TecJet.
Cause
Corrective action
TecJet setting is not correct.
u
Check setting.
1.4550.031 – A - Internal Fault
Red alarm. Initiated by ProAct A-Bank.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart ProAct.
1.4550.032 – A - Stop commanded (Run/Stop)
Yellow alarm. Initiated by ProAct A-Bank.
Cause
Corrective action
ProAct setting is incorrect.
u
Check setting.
1.4550.033 – A - Input (Supply) Voltage Fault
Yellow alarm. Initiated by ProAct A-Bank.
Cause
Corrective action
Supply voltage has reached
maximum or minimum limit
value.
1. Check supply voltage.
2. Check cabling.
1.4550.034 – A - Position Error
Red alarm. Initiated by ProAct A-Bank.
Cause
Corrective action
Position specification and
feedback signal do not match
u
Check mechanical system. Restart ProAct.
1.4550.035 – A - Temperature Sensor Fault
Red alarm. Initiated by ProAct A-Bank.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart ProAct.
MS150115/00E 2013-10
| Troubleshooting | 91
TIM-ID: 0000038611 - 002