1.4520.256 – Open Primary, Channel 12
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.257 – Open Primary, Channel 13
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.258 – Open Primary, Channel 14
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.259 – Open Primary, Channel 15
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.260 – Open Primary, Channel 16
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.262 – Open Primary, Channel 17
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.263 – Open Primary, Channel 18
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
80 | Troubleshooting | MS150115/00E 2013-10
TIM-ID: 0000038611 - 002