Fault code
Fault message
Meaning
Action
267
SD SP. DEM. TEST
BENCH
External test bench speed
setting faulty.
Check potentiometer and cabling
(→ Engine operating instructions).
270
SD SPEED DE‐
MAND
Sensor fault frequency set‐
ting.
1. Check cabling (→ Engine oper‐
ating instructions);
2. Contact Service
• Check setpoint speed sen‐
sor.
301...310
TIMING CYLINDER
(A1- A10)
Timing bank 1 (solenoid
valve 1) ... Timing bank 1
(solenoid valve 10)
Replace injector if fault message oc‐
curs frequently (→ Engine operating
instructions).
311...320
TIMING CYLINDER
(B1- B10)
Timing bank 2 (solenoid
valve 1) ... Timing bank 2
(solenoid valve 10)
Replace injector if fault message oc‐
curs frequently (→ Engine operating
instructions).
321...330
WIRING CYLINDER
(A1- A10)
Wiring bank 1 (solenoid
valve 1) ... Wiring bank 1
(solenoid valve 10)
Contact Service.
• Check solenoid valve.
331...340
WIRING CYLINDER
(B1- B10)
Wiring bank 2 (solenoid
valve 1) ... Wiring bank 2
(solenoid valve 10)
Contact Service.
• Check solenoid valve.
341...350
OPEN_LOAD CYL.
(A1- A10)
Open load bank 1 (sole‐
noid valve 1) ... Open load
bank 1 (solenoid valve 10)
Contact Service.
• Check solenoid valve.
351...360
OPEN_LOAD CYL.
(B1- B10)
Open load bank 2 (sole‐
noid valve 1) ... Open load
bank 2 (solenoid valve 10)
Contact Service.
• Check solenoid valve.
361
POWER STAGE
FAIL 1
Fault in ECU (solenoid
valve output stage bank 1).
(→ Engine operating instructions)
1. Check solenoid valve cabling.
2. Replace engine governor.
362
POWER STAGE
FAIL 2
Fault in ECU (solenoid
valve output stage bank 2).
(→ Engine operating instructions)
1. Check solenoid valve cabling.
2. replace engine governor.
363
STOP STAGE FAIL 1 Fault in solenoid valve, ca‐
bling or ECU;
automatic engine shut‐
down.
1. Check cabling (→ Engine oper‐
ating instructions).
2. Attempt to restart engine.
364
STOP STAGE FAIL 2 Fault in solenoid valve, ca‐
bling or in ECU;
automatic engine shut‐
down.
1. Check cabling (→ Engine oper‐
ating instructions).
2. Attempt to restart engine
365
STOP MV-WIRING
Fault in solenoid valve ca‐
bling;
automatic engine shut‐
down.
1. Check cabling (→ Engine oper‐
ating instructions).
2. Attempt to restart engine.
371
TRAN.OUT1 EN‐
GINE DEF
Binary transistor output en‐
gine 1 faulty.
(→ Engine operating instructions)
• Check charger valve/cabling re‐
pair as necessary
• Replace engine governor.
372
TRAN.OUT2 EN‐
GINE DEF
Binary transistor output en‐
gine 2 faulty.
(→ Engine operating instructions)
• Check air recirculation valve/ca‐
bling repair as necessary.
• Replace engine governor.
MS150025/02E 2012-10 | Troubleshooting | 71
TIM-ID: 0000008959 - 001