9 . 2 1
D e f r o s t c y c l e
The defrost cycle is a function that works only in heat pump mode and is used to prevent the formation of ice on the surface of the air/air
battery. The formation of ice on the evaporator, which occurs more frequently for very low temperatures of the external environment, in
addition to greatly reducing the thermodynamic efficiency of the machine, leads to the risk of damaging the machine itself.
9 . 2 2
C o m p r e s s o r c r a n k c a s e h e a t e r
The crankcase heater is activated when the compressor is off for at least 30 minutes and if the discharge temperature is below a certain
threshold (20°C with a hysteresis of 2.0°C). The crankcase heater is disabled when the compressor restarts.
9 . 2 3
F u n c t i o n s w h i c h c a n b e e n a b l e d w i t h H i - T a c c e s s o r y
9.23.1
Screed function
A function is implemented in the machines for connecting the screed in radiator systems installation. This function can be activated only if
the
Hi-T
accessory is installed, therefore for more information, refer to the manual of this control.
9.23.2
Disinfection (Legionella prevention)
The legionella prevention disinfection function is implemented in the machines. This function is enabled only if the
Hi-T
accessory is
installed, therefore for more details refer to the manual of this control. The parameters related to disinfection are:
•
r25
: Disinfection setpoint (anti-legionella) (in °C);
•
r26
: Disinfection duration (in minutes);
•
r27
: Heat pump in disinfection mode operation setpoint (in °C).
9 . 2 4
H a n d b o o k f o r i n s t a l l a t i o n c o n f i g u r a t i o n s
In case of need for clarification on the possible configurations, a “Handbook”has been prepared, which is a technical book consisting of a
collection of system diagrams which highlights some of the proposed installation configurations of our high efficiency heat pumps. The
“Handbook” also sets the task of showing the symbiosis potential with some of our items in the catalogue.
Ask the Head Office in order to consult the technical handbook.
9 . 2 5
T a b l e s o f s e t t i n g s w h i c h c a n b e m a d e b y t h e u s e r a n d i n s t a l l e r
Parameter
Description
Unit
Default
Range
Visibility
Permitted settings
Notes
Coo
First cooling
setpoint
°C
7.0
5.0÷Co2
U
Hea
First heating
setpoint
°C
45.0
He2÷55.0
U
San
Domestic hot water
setpoint
°C
48.0
25.0...55.0
U
Co2
Second cooling
setpoint
°C
18.0
Coo÷23.0
U
He2
Second heating
setpoint
°C
35.0
25.0÷Hea
U