Table 4
REPLACEMENT OPERATION
No.
OPERATION ORDER
(A set-point not met)
STATUS
OPERATION
r10
r15
r12
r16
r23
r24
1
1)
Hot water tank
2) After r12 minutes,
System backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
0/1
0/1/2
set the
minutes
/
4/6
1/3
2
1)
System backup
heater
2) After r12 minutes,
hot
water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
0/1
0/1/2
set the
minutes
/
1/3
1/3
3
1)
Hot water tank
2) After r12 minutes,
Domestic hot water
backup heater
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
0/1/2
/
set the
minutes
5/6
2/3
4
1)
Domestic hot water
backup heater
2) After r12 minutes,
hot
water tank
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
0/1/2
/
set the
minutes
2/3
2/3
5
1)
Hot water tank
2) After r12 minutes,
System/domestic hot
water backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
0/1
0/1/2
set the
minutes
set the
minutes
6
3
6
1)
System/domestic hot
water backup heater
2) After r12 minutes,
hot
water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
0/1
0/1/2
set the
minutes
set the
minutes
3
3
7
1)
Hot water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
0/1
0/1/2
set the
minutes
/
1/3/4/6
0/2
8
1)
System backup
heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
0/1
0/1/2
set the
minutes
/
0/2/5
1/3
9
1)
Hot water tank
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
0/1/2
/
set the
minutes
2/3/5/6
0/1
10
1)
Domestic hot water
backup heater
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
0/1/2
/
set the
minutes
0/1/4
2/3
11
1)
Hot water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
0/1
0/1/2
set the
minutes
set the
minutes
3/6
0
12
1)
System/domestic hot
water backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
0/1
0/1/2
set the
minutes
set the
minutes
0
3