TECHNICAL MANUAL
Chapter 9
- User - Control Interface
NGSi 05÷15
25
ENGLISH
EN
The data in this manual are not binding and they can be modified by the manufacturer without notice.
Reproduction of this manual is strictly prohibited
Table 1
HEAT PUMP NORMAL OPERATION
No.
BACKUP
OPERATIONS ORDER
(A set-point not met and
with the machine in
cutout alarm)
STATUS
OPERATION
r10
r15
r12
r16
r23
r24
1
1)
System backup
heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
1
0/1/2
/
/
0/2/5
1/3
2
1)
Hot water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
0/1
0/1/2
/
/
1/3/4/6
0/2
3
1)
System backup
heater
2) After r12 minutes,
hot
water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
1
0/1/2
set the
minutes
/
1/3
1/3
4
1)
Hot water tank
2) After r12 minutes,
system backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
1
0/1/2
set the
minutes
/
4/6
1/3
5
1)
Domestic hot water
backup heater
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
1
/
/
0/1/4
2/3
6
1)
Hot water tank
HEAT+SAN/
COOL+SAN
domestic hot
water
0/1
0/1/2
/
/
2/3/5/6
0/1
7
1)
Domestic hot water
backup heater
2) After r15 minutes,
hot
water tank
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
1
/
set the
minutes
2/3
2/3
8
1)
Hot water tank
2) After r15 minutes,
domestic hot water
backup heater
HEAT+
DOMESTIC
HOT WATER
domestic hot
water
0/1
1
/
set the
minutes
5/6
2/3
9
1)
System/domestic hot
water backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
1
1
/
/
0
3
10
1)
Hot water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
0/1
0/1/2
/
/
3/6
0
11
1)
System/domestic hot
water backup heater
2) After r12 minutes,
hot
water tank
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
1
1
set the
minutes
set the
minutes
3
3
12
1)
Hot water tank
2) After r12 minutes,
system/domestic hot
water backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
both in heat
mode and
domestic hot
water mode
1
1
set the
minutes
set the
minutes
6
3
Table 2
JOINT OPERATION, RANGE 1
No.
OPERATION ORDER
(A set-point not met)
STATUS
OPERATION
r10
r15
r12
r16
r23
r24
1
1)
Heat pump
2) After r12 minutes,
system backup heater
HEAT /
HEAT+
DOMESTIC
HOT WATER
heat
1
0/1/2
set the
minutes
/
0/2/5
1/3