23
a group of websites will auto reset, when all sites within that group timeout.
NOTE: Assignment cannot be for a combination of both and single outlets.
Site Label:
Give the IP address a short and easy to remember nickname. Max 16
characters.
Website / IP Address:
Enter a reliable website / IP address to ping.
Response Time:
The time it takes for a website to respond.
Protocol:
Select a suitable ping method for the website. Either a ping (UDP protocol) or a
web request (TCP protocol).
NOTE: The target site can be a Domain Name, IP Address or even LAN IP
Address – e.g. the router’s IP or local device on the router such as an IP
Camera.
ii.
Outlet Setup
Outlet 1/ 2 Name:
Give each outlet a name to easily identify the connected device (eg. router, modem,
etc).
Power-on Delay for Outlet 1:
Apply a delay (Power Off > Delay > Power On) to outlet #1’s power-cycle sequence.
Default is 3 seconds
– configurable from 1-600 seconds
.
Power-on Delay for Outlet 2:
Apply delay to Outlet 2, which takes place after Outlet 1 is reset. In default
configuration, Outlet 1 resets within 3 seconds and 13 seconds later, Outlet 2 resets.
Default 10 seconds – configurable from 1-600 seconds.
NOTE: Power Reset feature applies not only to the Reset here (Off > Delay >
On), but also to scheduled or manual resets. Only outlets that are currently
powered on will power cycle upon an auto reset.
iii.
Time-out Settings