3. APPROPRIATE USE
1. The bench is used only for its intended purpose (see sect. INTRODUCTION).
2. In the test area, it is prohibited to carry out any repair work on the shock absorber. This may
lead to the breakdown of the bench.
3. The shock absorber mounts securely in the pneumatic clamp. Do not allow any backlash
between the shock absorber and pneumatic clamps. This will result in unreliable diagnostic data
and a breakdown of the bench.
4. It is prohibited to test a knowingly defective shock absorber and shock absorber with a spring.
5. The bench shutdown should be performed through the interface of the service program, by
clicking on the «Turn off the bench». After the monitor goes out, you can turn the «ON/OFF»
button into the «OFF» position.
6. Use the button
«EMERGENCY STOP»
only if necessary to stop the diagnostic process in an
emergency.
7. The touch screen saving uses the stylus (supplied as a set).
8. The bench operating is prohibited in a defective condition and not connected to the ground.
9. To avoid damage or failure of the bench, it is not allowed to make changes to the bench at
one's discretion. The bench cannot change by anyone other than the official manufacturer.
10. Computer equipment and software use not designed to work with this bench voids warranty
obligations (even if the software and equipment were subsequently deleted). Only the original
MSG equipment software can be installed on this hardware.
11. In the case of a breakdown in the operation of the bench, it should be stopped further and
contact the manufacturer or the sales representative.
3.1. Safety regulations
1. Specially trained persons who have been given the right to work at the bench of certain types
and who have been instructed on safe techniques and working methods are allowed to work with
the bench.
2. Electrical supply of the bench is prohibited to turn on with the open doors of the mechanical
and/or electrical compartments. It is also PROHIBITED to open the door of the electrical
compartment until 10 minutes after the power is cut.
3. Shock absorber on the bench mounting and then dismantling is extra careful to prevent the
unit from falling.
4. The workplace shall always be clean, well-lit, and have enough free place.
5. The bench disconnects from the electrical network before starting any maintenance work.
6. To ensure electrical and fire safe PROHIBITED:
- connect the bench to the electrical network having faulty protection against current
overloads or not having such protection;
- to use a socket without a grounding contact to connect the bench;