1. Clean the powder gun as described in paragraph
interruption of work.
2. Remove the nozzle (1) from the nozzle tube.
3. Unscrew the nozzle nut (2) from the gun body (4).
4. Carefully pull out the nozzle tube (3) without twisting
the gun body.
5. Clean the removed nozzle and powder gun with
compressed air.
Replacing the Nozzle
3
4
WA R N I N G
!
CAUTION
!
When removing and inserting the nozzle holder,
always make sure the contact points are clean and
undamaged.
Do not clean the nozzles with solvent.
Under all circumstances the manual
powder guns must be dismounted for cleaning.
(Connection cable etc.).
There can be no guarantee for the safety of
the user.
1. Insert the nozzle tube, making sure the area is clear
and the contacts are lined up.
2. Screw the nozzle nut over the nozzle tube.
3. Insert the nozzle over the tube. Insert up to stop.
4. Carefully pull out the nozzle tube (3) without twisting
the gun body (4).
5. Clean the removed nozzle and powder gun with
compressed air.
3
4
2
2
1
4
3
PA-18-02-R0 (08/2018)
49 / 52
www.carlisleft.com
EN