General Problem
Possible Cause
Solution
TROUBLESHOOTING GUIDE
Defective fuse on the controller
Error at the high-voltage generation
Defective Cascade in spray gun
Defect electric cable from gun to
Controller
Incomplete grounding
No grounding
Compressed air main supply
insufficient
Feed air - dosage air ratio incorrect
Worn collector nozzle, propelling nozzle
in the injector
Worn nozzle system
Replace fuse
Contact MS Service
Contact MS Service
Contact MS Service
See chapter Grounding
See chapter Grounding
Check the air supply
Feed air, dosage air check to Controller
Check, Replace
Replace nozzle system
No electrostatics
and no powder
output
No electrostatic
(e.g. no wrap
around or no
powder adhesion)
Worse wrap around
Back spray
Powder outlet
insufficient
Spray cloud no
longer correct