16
eTEMPO/PLUS
®
CONTROLS
Installation Instructions for eTempo/Plus
®
Step 1
Determine the desired installation location of the control.
The eTEMPO/Plus controls are designed to be installed outside the
steam room in a location only accessible by the faculty operator.
The control cable length is 30 feet. Insure that the control and/or
steam generator are located accordingly. Contact a Mr.Steam tech-
nical service representative if a longer cable is required. Contact
Mr.Steam for optional 60 ft. cable, PN
103990-60
A Remote Temperature Probe Part Number MSTS-60 must be
installed inside the steam room.
• Do not locate the control above or near the steam head or
direct steam emissions.
IMPORTANT: See installation instructions for the MSTS
Temperature Probe before rough-in or installation of control
(pgs. 19-20).
Step 2
Make a one-inch diameter hole in the desired control location
(Diagram
1
). Do not oversize or undersize the hole.
Step 3
Route the control cable (provided with the control) from the wall
cutout to the steam generator. Connect the black round Mini-Din
connector to the steam generator connector as shown in Diagram 2.
NOTE:
The connector is keyed with the flat facing up.
IMPORTANT:
Be careful not to strain, staple, pinch or
otherwise damage the control cable. Route cable as required
to permit replacement. Do not install cable in a metal
conduit.
DIAGRAM 1
DIAGRAM 2