18
CT-S
TEAM
S
TOP
™
On/Off Switch for eTempo/Plus
®
Dimensional Information
Box Contents:
• CT-S
TEAM
S
TOP
Control
• Owner’s Manual
• Control Cable
INSTALLING THE
CT-STEAMSTOP
™
CONTROL
The CT-STEAMSTOP has a 30 foot cable with a Plug & Play
connector at both ends. (Diagram
1
)
A 60 foot control cable is available (103978-60).
Contact a Mr.Steam technical service representative if a longer
cable is required.
The CT-STEAMSTOP must be installed inside the steamroom.
STEP
1
-
Diagram
2
Drill a
7
⁄
8
inch diameter hole in a preferred wall location.
Do not oversize or undersize the hole.
STEP
2
-
Diagram
3
Route the cable from the wall to the steam generator. Be careful
not to strain, pinch or otherwise damage the control cable.
STEP
3
-
Diagram
4
Remove and discard the peel-off paper from the switch housing
to expose the adhesive as shown in Diagram 4.
STEP
4
-
Diagram
5
Apply silicone (provided with eTEMPO/PLUS control) to the hole in
the wall as required to create a moisture seal. Apply silicone to the
back of the switch as required to seal grout lines or as required for
additional adhesion.
IMPORTANT:
Use care not to apply silicone to the
adhesive gasket.
STEP
5
Push cable and switch housing into the hole firmly.
STEP
6
-
Diagram
6
Firmly connect the Plug & Play connector to the steam
generator connector labeled CT-STEAMSTOP.
NOTE:
The connector is keyed and will only connect
in one orientation with the tab facing up.
30
' CABLE
SWITCH
PLUG & PLAY
CONNECTOR
DIAGRAM 1
DIAGRAM 2
DIAGRAM 3
DIAGRAM
4
DIAGRAM
5
DIAGRAM
6
mr
.
steam
®
club therapy
®
eTempo Controls
______________________________________________________________________________