Force On
Test Button
DRAIN PAN
Mr. Steam provides a drain pan in the unlikely event of a plumbing leak.
Locate the drain pan on a solid level surface and place
the steam generator inside the drain pan. Insure the
steam generator is level (see page 4 for locating the
steam generator).
All plumbing shall be performed by a qualified licensed plumber and in
accordance with applicable national and local codes. Check local plumbing
code for receptor, trap and vent requirements. Drain pans drain by gravity.
The drain pan is equipped with an integral
3
⁄
4
" NPT fitting.
EXPRESS STEAM
(Factory installed)
All CT models have Express Steam standard.
Express Steam is equipped with a low power heating
element and thermostat to keep the water in the tank
warm enough to bring up steam quicker. All Express Steam
components and wiring are installed at the factory. No
additional wiring or plumbing is required by installers.
LIQUID LEVEL CONTROL BOARD - Explanation of LED Indicators
_______________________________________________________________________________________________
GREEN
LED is ON when there is 208/240 Volt incoming power connected,
24 Volt transformer secondary output and on-board 5 Volt DC control power are present.
_________________________________________________________________________________________________
YELLOW
Water level indicator–LED is OFF when no water is detected (for more that 5 seconds). ON when
water level is satisfactory. For units with AutoFlush, if more than five hours have elapsed since
last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction.
_________________________________________________________________________________________________
RED
Contactor relay indicator–LED is ON when relay is closed and sending 24 Volts to the
contactor coil. (This LED comes ON if the generator is ON.)
_________________________________________________________________________________________________
FORCE ON
This button is for trouble shooting only and will operate if a control is connected or not.
TEST BUTTON Pressing the button again will shut the generator OFF.
The test button will only allow the generator to operate for 10 minutes.
Liquid Level Control Board PN
103975
(shown without wiring)
12
mr
.
steam
®
club therapy
®
Installation, Operation & Maintenance Manual