11
AUTOFLUSH
®
Box Contents
• AutoFlush Valve with Cord
• Installation instructions.
Operation
The optional AutoFlush System feature automatically
drains the CT system following each use.
A time delay allows the water to cool down (about
two hours) before it drains by gravity for a safe and
gentle operation.
Unit drains by gravity.
Installation Instructions
1.
Plumbing to be performed by a qualified plumber
and shall be in accordance with applicable national
and local codes. Unit drains by gravity. A drain line
that is lower than the AutoFlush assembly must
be available. The AutoFlush System valve outlet is
threaded
1
" NPT. Check plumbing code for receptor,
trap and vent requirements.
2.
Use copper or brass nipple
1
" NPT x 3
1⁄2
" or longer (not supplied)
to connect AutoFlush valve (end "B") to the Drain Valve (valve
end “A” and “B” are indicated on bottom of AutoFlush Valve)
DO NOT REMOVE THE DRAIN VALVE
Removal may cause equipment and property damage.
If there is not enough room for the valve, an elbow and
a short nipple (not provided) can be added.
3.
Open Drain Valve (handle must be aligned with brass nipple).
4.
Connect the AutoFlush System cord connector to
the three pin connector as shown.
Do not drain into a steam enclosure or any
location where accidental contact with drain water may occur.
In the event of a power failure the AutoFlush System valve will
open and may discharge boiling water.
Sweat Fittings
When using sweat fittings use only tin base solder with a melting
point below 600 degrees F. Do not overheat. Ends of water supply
tubing must be thoroughly clean for a minimum distance of 1"
from ends. Do not remove valve cover.
To Check Operation
1.
Turn on Mr.Steam and allow tank to fill with water.
2.
Turn off Mr.Steam control. Water should stay in tank.
3.
Turn off power at the panel box. Water should
discharge from tank.
4.
Turn on power at panel box.
5.
Repeat
!
C A U T I O N
!
WA R N I N G
!
C A U T I O N
Drain Valve
DO NOT TURN OR REMOVE THE DRAIN VALVE
(shown in the correct open position)
Steam Generator
Nipple
Plumb to
Drain Line
AutoFlush Valve
AutoFlush Cord
AutoFlush Valve
3
Pin Connector
for AutoFlush
AutoFlush Cord
Connector
Drain Valve
(shown in the correct open position)
DO NOT REMOVE THIS DRAIN VALVE
Steam Generator
Nipple
copper or brass
nipple
1
" NPT x
3
1
⁄
2
"or longer
(not supplied)
End
"B" End
"A"
Plumb to
Drain Line
Arrow indicates correct
direction of flow
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL
CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
mr
.
steam
®
club therapy
®
Installation, Operation & Maintenance Manual
______________________________________________________________________________