19
7.3.3.2.
Mill Applications
▪
Typical Mill installations require one port and one alarm signal.
▪
Locate ‘Through Spindle’ contactor in machine cabinet. (Please refer to machine tool electrical
drawing booklet.)
▪
Wire #1 and #5 are to be used when using machine tool voltage.
▪
Wire #1 and #9 are used when put across dry contact. (Terminals 13 and 14 NO)
▪
Remove 3 phase power from bottom of low pressure TSP contactor.
▪
Some TSP setups require a second supply pump to be disconnected as well.
▪
Wire NC connections in series with TSP overload circuit.
▪
Wire NO connections in parallel with TSP overload circuit.
▪
Additional machine alarms may need to be jumped out.
7.3.3.3.
Lathe Applications
▪
Typical lathe configurations consist of wiring in series with the existing low pressure contactor
along with an external M Code. This allows for both low and high pressure pumps to be
utilized.
▪
Wiring through low pressure contactor before external M Codes ensures the MP V Series
Pump will shut down whenever machine is in hard alarm.
▪
Typical lathe applications use wire #9 to 24vdc from V Series through a series of dry
contacts.
▪
Wire NC connections in series with low pressure coolant overload circuit.
▪
Wire NO connections in parallel with low pressure coolant overload circuit.
▪
Additional machine alarms may need to be jumped out.
▪
Parameters may need to be set in order to latch external M Code functions
*Subject to change please refer to schematics in rear of manual .See Insert for Machine-Specific
Signals and Keep Relay instructions*