18
Wire #
V-2
19
Pin (
8
Port)
Function
1
PORT 1
Turns on Port 1
2
PORT 2
Turns on Port 2
3
PORT 3
Turns on Port 3*
4
PORT 4
Turns on Port 4*
5
0v
0v Common
6
Dump Valve On*
Opens Dump Valve*
7
ALARM COM 24v
24 Vdc
8
NC ALARM OUT
Opens on MP Fault
9
+24 Vdc
+24 Vdc from MP Pump
10
PORT 5
Turns on Port 5
11
PORT 6
Turns on Port6
12
PORT 7
Turns on Port 7
13
PORT 8
Turns on Port 8
14
N/A
N/A
15
N/A
N/A
16
NO ALARM
Closes on MP Fault
17
N/A
N/A
18
N/A
N/A
19
N/A
N/A
GRN
PE
Ground