7.4.2.1.
Variable/Adaptive Series PLC Settings (VR Series)
3434 [
] – Setup Menu
RESERVOIR SKIM SETUP
-
Enable/disable tank skim function and displays
time duration between tank skim events when
enabled.
Default = (0)
ALARM LATCH
–
Sets alarm output as a latching signal (which
keeps its state constant when triggered) or
pulsing signal (which changes state for 5
seconds before reverting).
Default = (0)
REDUCED PRESSURE LATCH
–
Sets the reduced pressure input as a latching
signal or pulsing signal.
Default = (0)
BINARY PRESSURE
–
Enables variable pressure to be controled by binary
input signal (two inputs, four pressures).
Default = 0
PRESSURE MEMORY
–
Starts system up at the last pressure value that was
selected before it was previously shut down.
Default = 0
I7 ASSIGNMENT
–
Switches function of input between operation of the
mist collector or the selection of pressure options for
variable presssure.
Default = 0
MIST COLLECTOR SIGNAL TYPE
–
Allows mist collector signal to exist as pulsing
or latching input (when using I7).
Default = 0
Summary of Contents for AK CB20
Page 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Page 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Page 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Page 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Page 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Page 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Page 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Page 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Page 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Page 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Page 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Page 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...