7.5.
Alarms
The machine uses one alarm output to interface with machine tool. If a fault occurs, a
signal is sent to the alarm circuit on machine tool, which, typically, will put machine tool
into a feed hold. The units PLC will display fault type.
Alarm will not clear off PLC display until fault has been rectified. Once fault has been
remedied, press
[
]
to clear alarm.
ALARM DISPLAY
SYMPTOM(S)
CAUSE
Slow Fill/Change Bag or Check
Feed Pump
Tank will not fill fast enough to
keep up with output.
Improper supply pump
rotation.
Clogged filter.
Priming issue.
Machine tool coolant
screen clogged.
Obstructed hoses.
Dip tube not fully
submerged.
C.B. TRIP RESET
ENTER TO CLEAR
Motor overload tripped
Electric motor short
cycle.
Electric motor shorting.
Load on motor to great.
Electric motor over load
set to low.
Electrical short in system
causing overload to trip.
Drive Alarm
Call MP Systems 877-
689-1860
Fault on VFD present in unit
Summary of Contents for AK CB20
Page 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Page 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Page 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Page 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Page 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Page 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Page 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Page 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Page 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Page 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Page 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Page 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...