18
MPSYSTEMS-M-001/06
6.3.3.
Control Signal Harness Installation
1. Mount supplied control signal harness with hardware provided in installation kit and route
cable;
Make sure R Series signal cable is able to reach mounted control signal harness.
If 1/2” conduit plug is not available, knock out hole and use supplied cord grip.
Be sure to leave enough cable to properly earth the unit.
Attach supplied jumper plug to control signal harness, using supplied zip tie.
If unit must be disconnected from machine tool, install supplied jumper plug to control
signal harness. This will allow machine tool to operate normally without alarm.
2. Wire signals required for desired pump function (R Series electrical diagrams are located in
electrical cabinet);
MP SYSTEMS
utilizes 24VDC signals for control.
i. 110VAC signals, relays will need to be installed.
Signals and M-Codes may vary between machine tools.
i. Please refer to machine tool electrical drawings booklet.
External M-Codes may require latching functions.
‘Normally Closed’ alarms are typically wired in
SERIES
with machine tool low pressure
pumps.
‘Normally Open’ alarms are typically wired in
PARALLEL
with machine tool low
pressure pumps.
3. Locate proper earthing point. Attach using supplied ring terminals.
MP SYSTEMS
recommends the use of the ‘Normally Closed’ alarm circuit when wiring in
to machine tool electrical cabinet.
When wiring control signals, be sure to take account of any accessories that were
purchased with R Series. Dual Pressure (DP), RC Chiller (RC), Variable Pressure, etc.
Summary of Contents for AK CB20
Page 15: ...9 MPSYSTEMS M 001 06 4 2 1 Floor Layout R VR SERIES 28 36 15 24 ...
Page 16: ...10 MPSYSTEMS M 001 06 RF16 RT VR16 VRT SERIES 15 24 38 42 ...
Page 25: ...19 MPSYSTEMS M 001 06 6 3 3 1 R RA11 Series Control Signal Explanation ...
Page 26: ...20 MPSYSTEMS M 001 06 6 3 3 1 1 Variable Adaptive Series Control Signal Explanation VR ...
Page 33: ...27 MPSYSTEMS M 001 06 6 5 3 8JIC to 6JIS Fitting Explanation ...
Page 72: ...66 MPSYSTEMS M 001 06 10 2 Relief Valve Identifier ...
Page 76: ...70 MPSYSTEMS M 001 06 JIS JIC Fittings Example 6 3 8 JIS 6 3 8 JIC 8 1 2 JIS 8 1 2 JIC ...
Page 77: ...71 MPSYSTEMS M 001 06 RF8 Series Flow Diagram ...
Page 78: ...72 MPSYSTEMS M 001 06 RFC Series Flow Diagram ...
Page 79: ...73 MPSYSTEMS M 001 06 RA11 Series Flow Diagram ...
Page 80: ...74 MPSYSTEMS M 001 06 RT Series Flow Diagram ...
Page 81: ...75 MPSYSTEMS M 001 06 RF16 Series Flow Diagram ...