B.REVERSAL HEIGHT IGNORANCE SETTING
a) Press and hold
SET
Button until “
1
” appears on the display,
next press the
UP
button until “b” appears on the display to
enter this function setting then release the button.
b) Press the
SET
button again. The unit is now in reversal
height ignorance adjustment mode. And then you will see a
figure “
1
” with flash dot appears on the display.
c) Press
UP
/
DOWN
button once to set the reversal height
ignorance while closing (0~9).
d) Press
UP
button to increase , or
DOWN
button to decrease.
Figure “1~9” means the door will still not rebound even
though there’s obstacles in its closing path within 1cm~9cm
away from the close position. This function is most suitable
for the Northern Europe where will always snow on the
ground.
e) Press
SET
button to confirm the set and it will back to
standby status automatically and display “ll”.
NOTE:
The reversal height is set on “
1
” as standard in factory.
C. PASS DOOR SWITCH TYPE SETTING
a) Press and hold
SET
Button until “
1
” appears on the display,
next press the UP button until “
C
” appears on the display to
enter this function setting then release the button.
b) Press the
SET
button again. The unit is now in the pass door
switch type adjustment mode. And then you will see a figure
“
0
” with flash dot appears on the display.
c) Press
UP
/
DOWN
button once to set the pass door switch
type. You can choose “
0
” or “
1
” set.
Figure “
0
” means, the pass door function is normally open.
Figure “
1
” means, the pass door function is normally close.
e) Press
SET
button to confirm the set and it will back to
standby status automatically and display “ll”.
NOTE:
The pass door switch is set on “
0
” as standard in
factory.
-17
D
-
increase height
decrease height
Summary of Contents for Force+ 1000N
Page 31: ......