PROGRAMMING INSTRUCTIONS
1. PROGRAMMING OPEN & CLOSE LIMITS
a) Press and hold
SET
button to enter this function setting
until “
1
” appears on the display then release the button.
b) Press the
SET
button again. The door opener is now in
Programming Mode. And then you will see “n” with dot
appears on the display.
c) Press and hold the
UP
button until the door reaches the
desired open position, you will see “n” without dot on the
display.
d) Press
SET
button to confirm the open position, then you
will see “u” with dot on the display.
e) Next press and hold the
DOWN
button until the door
reaches the desired close position, you will see “u” without
dot on the display.
NOTE: For fine adjustments toggle
UP
&
DOWN
buttons.
f) Now press the
SET
button to confirm the close position,
then you will see “II” on the display.
After confirm the close position, the door will now cycle
open and close to set the travel limits and force sensitivity
adjustments. The door is now set for normal operation.
CAUTION:
After the cycle open and close, there will be
figures shown on the display (0~9), “0” means the doors is
balanced, the smaller figure means the better door balance,
strongly recommend that the figure need to be smaller than
the power force.
-10
D
-
Summary of Contents for Force+ 1000N
Page 31: ......