9. PC communication software,
Hi-Manager (for MS Windows)
With free PC communication software, Hi-Manager, it is easy to set the parameters
including torque, speed, fastening monitoring and quality control.
For changing parameters of controller by PC software, it require Log-in password.
For the manager Log-in password of Hi-Manager software, please contact to the
distributor or service center. The password can not be open to operators without
agreement of managing group. Hi-Manager without Log-in is available by request, too
9.1 Software
install
- PC Operating System : MS Windows ( 2000, XP, Vista, WIN7, WIN8 )
- Display : 1024 x 768 ( Optimized )
The Hi-Manager software require MS Dot Net framework v 2.0 or higher on your OS
before install.
Window 2000 and XP can be updated with Dot Net framework on the download center
of Microsoft web site. ( www.microsoft.com ).
Microsoft .NET Framework ver 4.0
For installation of Hi-Manager, just copy the file ( Hi-Manager.exe ) on your PC, and
double click for open.
9.2 How to use
- Install the provided USB driver (HDC USB driver) on your PC
- Connect the HDC controller to PC, and Power on.
- Check COM port no. for HDC USB port on your PC.
example )
CP210x USB to UART Bridge Controller
(COM4)
- Open the
Hi-Manager
software
- Select the Comport no and click OK
- Click " READ ALL " menu for read all parameters from the connected HDC controller.
- For changing parameter, it require Manager Log-in password.
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
77