Description
If there is difference between set torque and reading torque on the
torque tester, the output torque can be adjusted from
-20% ~ +20%
This compensation effects to whole range of torque.
This torque compensation value is saved in screwdriver itself.
80 (-20%) ----> 100 (100%) <---- 120 (+20%)
Example) 105 : + 5% from the current torque (Increase)
90 : - 10% from the current torque (Decrease)
16) Define of I/O interface
`
Number
Unit
Range
Initial
P64
0 ~ 4
0
Description
The I/O interface which are connected to Direct Sensor port
and 25P I/O port can be used with one of following function.
"0" : Manual operation with direct sensor port
IN
: preset # selecting through 1 to 8 port.
OUT
: Selected preset # display through 10 to 17 port
"1" : Remote control by PLC with 25P I/O port
IN / OUT
: for PLC
"2" : Combined IN/OUT
IN
: preset # selecting through 1 to 8 port. (Manual)
OUT
: for PLC
"3" : Manual operation with 25P I/O port
IN / OUT
: for PLC except Start, For/Rev selection on
the screwdriver
"4" : Connected to " Socket Tray "
17) Beep sound ON/OFF