Number
Unit
Range
Initial
P65
0 or 1
0
Description
The beep sound can be off
0 : ON 1 : OFF
18) Time limit for fastening, Loosening and motor stall
Number
Unit
Range
Initial
P66~68
0.1 sec
0 ~ 60.0
Description
It prevent the continuous running over the preset time in direction of
fastening and loosening for safety operation. The driver stops
automatically at the preset time and provide the pattern NG with the
error code below;
P66 : Limit of fastening run time error code - E300
P67 : Limit of loosening run time error code - E302
Initial value = 10.0 sec
Also it prevent the continuous time going against the motor stall for
over heat protection.
P68 : Limit of motor stall time
error code - E303
Initial value = 1.0 sec
19) Reverse control
Reverse can be activated or deactivated
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
31