22
Input COM
5.11.3 25P I/O configuration (
Ⅲ
) -
for Torque selector by Sensor (Input) + PLC (Output)
[ P64 Setting ] - " 2 " : Combined
PIN no.
Configuration
IN / OUT
1
Torque select IN1
INPUT
(to Controller)
2
Torque select IN2
3
Torque select IN3
4
Torque select IN4
5
Torque select IN5
6
Torque select IN6
7
Torque select IN7
8
Torque select IN8
9
Reset ( include cycle reset )
or Work-piece move OUT from area
(P76 "3" selected )
19
Work-piece move IN to area
23
x
24
x
10
Error code OUT1
OUTPUT
(to Controller)
11
Error code OUT2
12
Error code OUT3
13
Error code OUT4
14
Status of F/R OUT (F:0, R:1)
15
Torque up
16
Status of Motor Run OUT
17
READY
18
ALARM (NG)
20
Cycle count complete
25
Fastening OK OUT
21
Output COM