Description
Factory setting password is " 0 " at the initial.
Password can be changed between 0 - 9999 on P89.
40) Screw numbers on each models
Number
Unit
Range
Initial
P90-97
0 ~ 20
0
Description
Screw numbers on each model 1 to 8 is saved on P90 to 97
P90 : Screw # of Model 1
P91 : Screw # of Model 2
P92 : Screw # of Model 3
P93 : Screw # of Model 4
P94 : Screw # of Model 5
P95 : Screw # of Model 6
P96 : Screw # of Model 7
P97 : Screw # of Model 8
Maximum screw number is 20 for each model.
41) Start signal OFF delay time
Number
Unit
Range
Initial
P
9
9
0 ~ 1000
0
Description
Customer lost the fastening OK output when operator release
start lever just before torque up, but clutch was activated by
inertia. Range : 0 - 1,000 mS factory setting : 10mS
42) Error history ( except the pattern error )
Number
Unit
Range
Initial
P160~167
1080 N 11th St San Jose CA 95112
www.mountztorque.com 408.292.2214
42