32
Type
Powerlog 10t
Hydraulic oil (max.)
10 litres
Splitting wedge force
100 kN (10t) ±10%
Hydraulic pressure
21.4 MPa (214 bar)
Max. log length
1300 mm
Motor output
P1 4.0 kW (S6 40%)
Log diameter
min. 120 mm – max. 400 mm
Power supply connection
400 V 3~ 50 Hz, 16 A slow
Splitting wedge travel
≈
515mm
Dimensions
Depth 580 mm x Width
530 mm x Height 1530
mm
Downward travel speed
approx. 0.05 m/sec
Weight
approx. 175 kg
Upward travel speed
approx. 0.17 m/sec
Technical data
Troubleshooting
Failure
Possible cause
Remedy
The log cannot be split
(poor performance)
X
Incorrectly positioned log
X
Turn and reposition the log in the
machine.
X
The log size exceeds the allowed
dimensions
X
Use a log of recommended dimen-
sions.
X
The splitting wedge does not split
X
Sharpen the splitting wedge and
check the cutting edge for wear or
notches.
X
Low oil pressure
X
Check the oil level. If the problem
persists, contact an authorised
service centre.
X
The releasing rod linkage is bent
(the hydraulic control lever is not
fully depressed)
X
Have the rod linkage repaired and
adjusted by the manufacturer or an
authorised service centre.
X
A cable longer than 10 meters or a
cable with small cross-section wire
is used
X
Use the correct cable according to
the specifi cation.
Irregular movement or strong
vibrations of the splitter co-
lumn when it is moving down
X
Air in the system
X
Check the oil level.
X
The splitter column is not properly
lubricated.
X
Lubricate the splitter column with
grease or oil spray. If the problem
persists, contact an authorised
service centre.
The splitter column cannot
be retracted
X
failure in the hydraulic system
X
Contact an authorised service centre.
The motor is running but
the splitter column does not
move
X
The motor is running in the wrong
direction
X
Check the three-phase motor for the
correct direction of rotation. Change
the direction of motor rotation.
The motor is not running
X
Power supply failure
X
Check the protection.
X
The three-phase motor is running
with 2 phases.
X
Have the fuse and power supply
checked by an electrician.
X
Defective power supply cable
X
Replace the power supply cable.
X
Defective motor
X
Contact an authorised service centre.