Ix350_02b_oi_e.doc / Mai-18
Page 49 / 50
6.7.
Technical Specifications:
Technical Specifications:
Connections:
Connector type:
screw terminal, 1.5 mm² / AWG 16
Power supply (DC):
Input voltage:
Protection circuit:
Consumption:
Fuse protection:
18 … 30 VDC
reverse polarity protection
approx. 150 mA (unloaded)
extern: T 0.5 A
Power supply (AC):
(Option AC)
Input voltage:
Power consumption:
Fuse protection:
115 / 230 VAC (60/50 Hz)
approx. 5 VA (unloaded)
extern: T 0.1 A
Encoder supply:
DC version:
AC version:
24 VDC (approx. 1 V lower than the power supply
voltage),max 250 mA
24 VDC (± 15%), (max 150 mA until 45°C / 80 mA by
more than 45°C)
Encoder supply:
(IX355)
DC version:
AC version
24 VDC (approx. 1 V lower than the power supply
voltage), max 250 mA or 5 VDC (± 15%), max. 250 mA
24 VDC (± 15%) (max 150 mA until 45°C / 80 mA by more
than 45°C)
or 5 VDC (± 15%), max. 250 mA)
SSI interface:
Number (channels):
Configuration:
Format:
Frequency:
Resolution:
Load:
1 (Clock, /Clock, Data, /Data)
Master or Slave
Binary or Gray code
Max. 1 MHz
10 … 32 Bit
Max. 2 mA / Ri > 10 kOhm / 47 pF
Control inputs:
Number of inputs:
Format:
Frequency:
Load:
3
HTL, PNP (10 … 30 V)
Max. 10 kHz
Max. 2 mA / Ri > 15 kOhm / 470 pF
Analog output:
(Option AO/AR)
Configuration:
Voltage output:
Current output:
Resolution:
Accuracy:
Reaction time:
current or voltage operation
-10…+10 V (Low 0 …3 V, High 9 …30 V)
0/4 … 20 mA (burden: max. 270 Ohm)
16 Bit
± 0,1 %
< 150 ms
Control outputs:
(Option AO/AR/CO/CR)
Number of outputs:
Format / level:
Output current:
Reaction time:
4
5 … 30 V (depends on the Com+ voltage), PNP
Max. 200 mA
< 1 ms
Relay outputs:
(Option RL)
Number of outputs:
Configuration:
AC-Switching
capacity:
DC-Switching capacity:
Reaction time:
2
potential free changeovers
Max. 250 VAC / 3 A / 750 VA
Max. 150 VDC / 2 A / 50 W
< 20 ms