5.6.
Preselection 3 Menu
MODE 3
Switching conditions for preselection 3., see chapter PRESELECTION 1 MENU (except the trailing value)
See chapter PRESELECTION 1 MENU
6
RES>=PRES-
TRAIL
Trailing preselection 3:
Display value is greater or equal to PRESELECTION 4 – PRESELECTION 3
ON,
PRESELECTION 3 is the trailing preselection from PRESELECTION 4.
HYSTERESIS 3
This parameter defines the switching hysteresis of the switch-off point for preselection 3.
See chapter PRESELECTION 1 MENU.
PULSE TIME 3 (S)
Duration of output pulse for the switching condition of preselection 3.
See chapter PRESELECTION 1 MENU.
OUTPUT TARGET 3
Assignment of an output or relay for the switching condition of preselection 3.
See chapter PRESELECTION 1 MENU.
OUTPUT POLARITY 3
Polarity for the switching condition of preselection 3.
See chapter PRESELECTION 1 MENU.
OUTPUT LOCK 3
Latch for the switching condition of preselection 3.
See chapter PRESELECTION 1 MENU.
START UP DELAY 3
Start-up suppression for the switching condition of preselection 3.
Time to start the monitoring function.
This adjustment is only valid for the switching condition |RESULT|<=|PRES| or RESULT<=PRES and mode SPPED
and PROCESS TIME. (Start Up Delay 1 and 2 have a time-dependent start up suppression).
0 OFF
No start-up suppression
1 AUTO
Automatic start up suppression,
Until the preselection value / switching point is exceeded for the first time.
EVENT COLOR 3
Event-depending change of the display color for the switching condition of preselection 3.
See chapter PRESELECTION 1 MENU.