Ix350_02b_oi_e.doc / Mai-18
Page 22 / 50
Continuation „SSI Properties“:
HIGH BIT
(for bit blanking)
Defines the highest evaluated bit (MSB) for bit blanking.
If all bits should be evaluated, HIGH BIT must be set to the given total number of bit.
01
Smallest value
25
Default value
32
Highest value
LOW BIT
(for bit blanking))
Defines the lowest evaluated bit (MSB) for bit blanking.
If all bits should be evaluated, LOW BIT must be set to 01.
01
Smallest value
…
32
Highest value
SSI OFFSET
In the case of a reset/Set value command (via keyboard command, control input or PC user interface) The current
SSI position of the encoder is transferred to the parameter "SSI offset".
-99999999
Smallest value
0
Default value
99999999
Highest value
DIRECTION
Definition of the direction of rotation forward / backward
0
FORWARD
Forward
1
REVERSE
Backwards
ROUND LOOP VALUE
Defines the number of encoder steps when a round-loop function is desired.
0
Normal display of encoder data, round-loop function is turned off
…
99999999
Number of steps for the round-loop function
SAMPLING TIME (S)
Determines the read cycle for the SSI signal in the Master MODE
0.001
Minimum measurement time in seconds
0.010
Default value
9.999
Maximum measurement time in seconds