Ix350_02b_oi_e.doc / Mai-18
Page 37 / 50
5.12.
Linearization Menu
The linearization function is defined in this menu. This menu will only be showed, if the
LINEARIZATION MODE in GENERAL MENU is selected.
Linearization description and examples are shown in the appendix.
P1(X) … P24(X)
X-coordinate of the linearization point.
This value representing the display value which the unit show in the display without linearization.
-99999999
Smallest X-coordinate
0
Default value
+99999999
Largest X-coordinate
P1(Y) … P24(Y)
Y-coordinate of the linearization point
This is the display value, which the unit should show in the display with linearization.
E.g. P2(X) is replaced by P2(Y).
-99999999
Smallest Y-coordinate
0
Default value
+99999999
Largest Y-coordinate