Ix350_02b_oi_e.doc / Mai-18
Page 30 / 50
5.7.
Preselection 4 Menu
If the BATCH MODE is active, the batch counter is compared with the preselection value 4.
MODE 4
Switching conditions for preselection 4., see chapter PRESELECTION 1 MENU (except the trailing value)
See chapter PRESELECTION 1 MENU
6 RES>=PRES-TRAIL
Trailing preselection 4:
Display value is greater or equal to PRESELECTION 3 – PRESELECTION 4
ON,
PRESELECTION 4 is the trailing preselection from PRESELECTION 3.
HYSTERESIS 4
This parameter defines the switching hysteresis of the switch-off point for preselection 4.
See chapter PRESELECTION 1 MENU.
PULSE TIME 4 (S)
Duration of output pulse for the switching condition of preselection 4.
See chapter PRESELECTION 1 MENU.
OUTPUT TARGET 4
Assignment of an output or relay for the switching condition of preselection 4.
See chapter PRESELECTION 1 MENU.
OUTPUT POLARITY 4
Polarity for the switching condition of preselection 4.
See chapter PRESELECTION 1 MENU.
OUTPUT LOCK 4
Latch for the switching condition of preselection 4.
See chapter PRESELECTION 1 MENU.
START UP DELAY 4
Start-up suppression for the switching condition of preselection 4. See chapter PRESELECTION 3 MENU.
(Start Up Delay 1 and 2 have a time-dependent start up suppression).
0 OFF
No start-up suppression
1 AUTO
Automatic start up suppression,
Until the preselection value / switching point is exceeded for the first time.
EVENT COLOR 4
Event-depending change of the display color for the switching condition of preselection 4.
See chapter PRESELECTION 1 MENU.