8 Settings via the MICT
86
Rev. 06/2020
You have the following options:
–
Save
The recorded values are saved on the connected computer as a CSV file. You can open and
process these in other programs such as Microsoft Excel
®
.
–
Clear
Deletes previously recorded data and starts a new recording.
–
Pause
The displaying of the values is paused. However, the recording of the values continues in the
background.
–
Show/Hide values
Use the checkboxes in front of the values to specify which values are displayed in the
diagrams.
The color of the fields behind the checkbox corresponds to the color of the respective curve
in the diagrams. The small symbol within the color fields indicates in which diagram the
corresponding value is displayed and to which scale the value refers. The label on the scale
does not always reflect all the values displayed.
Examples:
– The actual value of the pump pressure is shown as a blue curve in the upper
diagram and the values are read off the left-hand scale.
– The P parameter of the PID control of the pump is shown as a green curve in
the lower diagram and the values are read on the right scale.
–
Change displayed time period
Using the drop-down menu, you can select the time period that is displayed in the diagrams.