4 Product Description
20
Rev. 06/2020
Feature
Value
Output for control signal
for pump speed
–
Open collector
–
Voltage: 18 V DC to 32 V DC
–
PWM: 100 Hz
–
Current: Max. 30 mA
Input for feedback signal
for pump speed
–
NPN with pull-up resistor 12 kΩ
–
Input voltage up to 32 V DC
–
Frequency: 0 Hz to 500 Hz (square wave signal)
Electrical Data for Connection of the Dosing Unit
The connections of the dosing unit have the following electrical data:
Feature
Value
Power supply of the
integrated sensors
5 V DC; max. 30 mA
Analog voltage input for
AdBlue
®
pressure
–
Permissible voltage: 0 V DC to 4.5 V DC
–
Measuring range: 0 bar to +19.5 bar abs. (0 psi to
+282.8 psi abs.)
–
Measuring tolerance: 2 % of measured value
Analog voltage input for
AdBlue
®
temperature
–
Permissible voltage: 3.3 V DC to 0.5 V DC
–
Measuring range: –50 °C to +150 °C (–58 °F to +302 °F)
–
Measuring tolerance:
+/–4 °C (in the range 0 °C to +90 °C)
+/–7.2 °F (in the range +32 °F to +194 °F)
Connection for the dosing
valve
PWM: 5 kHz, 18 V to 32 V; max. 1 A
Connection for the heating
resistor
Power supply: 18 V DC to 32 V DC; max. 2 A
Electrical Data of the Connections for the Sensors on the Catalytic Converter
The connections of the sensors have the following electrical data:
Feature
Value
Power supply of the
sensors
18 V DC to 32 V DC; max. 1.5 A
Summary of Contents for VariSCR
Page 1: ...VariSCR NOX Emission Controller Operating Manual P N 01 50 025 EN Rev 06 2020...
Page 111: ...Rev 06 2020 111...