6880309U09-A
October 26, 2007
Basic Maintenance
: Handling Precautions
2-3
• Use a static-safeguarded workstation, through the use of a wrist strap, two ground cords, a
static-control table mat and a static-control floor mat.
NOTE:
Be sure that the table and floor mats are properly grounded.
When these items are not readily available, observing the following techniques will minimize the
chance of damage:
• If a static-sensitive device is to be temporarily set down, use a conductive surface for
placement of the device.
• Make skin contact with a conductive work surface first and maintain this contact when the
device is set down or picked up.
• Always wear a conductive wrist strap when servicing this equipment. The Motorola part number
for a replacement wrist strap that connects to the table mat is 4280385A59.
Summary of Contents for PM1200
Page 1: ......
Page 2: ......
Page 6: ...iv Notes ...
Page 30: ...October 26 2007 6880309U09 A 2 4 Basic Maintenance Handling Precautions Notes ...
Page 38: ...October 26 2007 6880309U09 A Notes 3 8 Basic Theory of Operation PLL Synthesizer ...
Page 108: ...October 26 2007 6880309U09 A Notes 7 4 Basic Troubleshooting Receiver Troubleshooting ...
Page 134: ...October 26 2007 6880309U09 A Glossary 8 Notes ...
Page 137: ......