2-102
Computer Group Literature Center Web Site
VMEchip2
2
The location monitor status register provides the status of the location
monitors. A location monitor bit is cleared when the VMEchip2 detects a
VMEbus cycle to the corresponding location monitor address. When the
LM0 or LM1 bits are cleared, an interrupt is set to the local bus interrupter.
If the LM0 or LM1 interrupt is enabled in the local bus interrupter, then a
local bus interrupt is generated. The location monitor bits are set by writing
a one to the corresponding bit in the location monitor register. LM0 and
LM1 can also be set by writing a one to the corresponding clear bits in the
local interrupt clear register.
The interrupt control register provides four bits that allow the VMEbus to
interrupt the local bus. An interrupt is sent to the local bus interrupter when
one of the bits is set. If the interrupt is enabled in the local bus interrupter,
then a local bus interrupt is generated. The interrupt bits are cleared by
writing a one to the corresponding bit in the interrupt clear register.
The board control register allows a VMEbus master to reset the local bus,
prevent the VMEchip2 from driving the SYSFAIL signal line, and detect
if the VMEchip2 wants to drive the SYSFAIL signal line.
The six general purpose registers can be read and written from both the
local bus and the VMEbus. These registers are provided to allow local bus
masters to communicate with VMEbus masters. The function of these
registers is not defined by this specification. The GCSR supports
read-modify-write cycles such as TAS.
!
Caution
The GCSR allows a VMEbus master to reset the local bus.
This feature is very dangerous and should be used with
caution. The local reset feature is a partial system reset, not a
complete system reset such as powerup reset or SYSRESET.
When the local bus reset signal is asserted, a local bus cycle
may be aborted. The VMEchip2 is connected to both the local
bus and the VMEbus and if the aborted cycle is bound for the
VMEbus, erratic operation may result. Communications
between the local processor and a VMEbus master should use
interrupts or mailbox locations; reset should not be used in
normal communications. Reset should be used only when the
local processor is halted or the local bus is hung and reset is
the last resort.
Summary of Contents for MVME172
Page 6: ...Place holder ...
Page 18: ...xviii ...
Page 78: ...1 60 Computer Group Literature Center Web Site Board Description and Memory Maps 1 ...
Page 332: ...5 42 Computer Group Literature Center Web Site MCECC 5 ...
Page 336: ...A 4 Related Documentation A ...
Page 352: ...Index IN 12 Computer Group Literature Center Web Site I N D E X ...
Page 354: ......