Maintenance & Troubleshooting 9 - 5
3.
Rub the cotton portion of the cotton tipped applicator along the pins of the connector. Slowly move the
applicator back-and-forth from one side of the connector to the other. Do not let any cotton residue on the
connector.
4.
All sides of the connector should also be rubbed with the cotton tipped applicator.
5.
Spray compressed air in the connector area by pointing the tube/nozzle about ½ inch away from the surface.
6.
Ensure that there is no lint left by the cotton tipped applicator, remove lint if found.
7.
If grease and other dirt can be found on other areas of the cradle, use lint free cloth and alcohol to remove.
8.
Allow at least 10 to 30 minutes (depending on ambient temperature and humidity) for the alcohol to air dry
before applying power to cradle.
If the temperature is low and humidity is high, longer drying time is required. Warm temperature and dry
humidity requires less drying time.
Cleaning Frequency
The cleaning frequency is up to the customer’s discretion due to the varied environments in which the mobile
devices are used. They may be cleaned as frequently as required. However when used in dirty environments it
may be advisable to periodically clean the scanner exit window to ensure optimum scanning performance.
Troubleshooting
MC45
CAUTION
Do not point nozzle at yourself and others, ensure the nozzle or tube is away from your face.
Table 9-1
Troubleshooting the MC45
Problem
Cause
Solution
MC45 does not turn
on.
Battery not charged. Charge or replace the battery.
Battery not installed
properly.
Install the battery properly. See
Installing the Battery on page 1-5
System crash.
Perform a warm boot. If the MC45 still does not turn on, perform a
cold boot. See
Resetting the MC45 on page 2-17
.
Rechargeable battery
did not charge.
Battery failed.
Replace battery. If the MC45 still does not operate, perform a warm
boot, then a cold boot. See
Resetting the MC45 on page 2-17
.
MC45 removed
from cradle while
battery was
charging.
Insert MC45 in cradle and allow to charge.
Extreme battery
temperature.
Battery does not charge if ambient temperature is below 0°C (32°F)
or above 40°C (104°F).
Summary of Contents for MC45
Page 1: ...b MC45 USER GUIDE ...
Page 2: ......
Page 3: ...MC45 User Guide 72E 164159 01 Rev A December 2012 ...
Page 6: ...iv MC45 User Guide ...
Page 12: ...x MC45 User Guide ...
Page 54: ...2 24 MC45 User Guide ...
Page 98: ...6 4 MC45 User Guide ...
Page 124: ...9 12 MC45 User Guide ...
Page 150: ...B 6 MC45 User Guide ...
Page 163: ......