Transtector ALPU-OR
Installed by Radio
Transtector ALPU-ORT
Installed by Grounding Stake
Transtector ALPU-ORT
Internal View
Note: The 150/300 Mbps Backhaul is not designed to survive direct lightning strikes. For this
reason the unit should not be installed as the highest point in a localized area, unless specific
precautions are taken. See section 12 “Lightning Protection”.
5.5
Electrical Requirements
The Canopy 150/300 Mb BH is supplied with a variable input voltage (100-240V, 47-63Hz
AC) inline power supply unit which is incorporated into the Power Indoor Unit (150/300 PIDU).
The Canopy 150/300 Mb BH requires one mains supply outlet at each end of the link.
An external AC surge suppression device is recommended for use with the Canopy 150/300
Mbps Backhaul. For infrastructure installations, Canopy Engineering recommends an AC line
surge suppression unit that meets the standard IEC 801-5 (EN61000-4-5) Class 5 at +/- 6
Kvolts on AC power source Line-Ground and +/- 4 Kvolts on Line-Line.