10
AP 6522M Access Point
2.4.2 Wall Mount Procedure
1.
Orient the case on the wall by its width or length.
2.
Mark two points (for drill holes) 4.08 inches (103.7 mm) apart on a horizontal or vertical line depending on
the desired cable exit direction. If mounted on a horizontal line, the cables will exit to the left or right. If
mounted on a vertical line, the cables will exit up or down.
3.
At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and
stop when there is 1mm between the screw head and the wall.
4.
Attach an Ethernet cable from the Access Point to a controller with an 802.3af-compatible power source
or use the PWRS-14000-148R power supply to supply power to the AP 6522M (once fully cabled).
CAUTION
To ensure proper operation of an AP 6522M Access Point, ensure it is
mounted in the correct orientation for the desired cable routing.
NOTE
When pre-drilling a hole the recommended hole size is 2.8mm (0.11in.).
!